AC30 Cuber with bin, 2 cube sizes air and water cooled.
In production from 1974 to 1997.
Ice production 258 to 173
lb./24 hours
Air cooled water use, ice | |
only*
84 gallons per 24 hours
Water use, water cooled
condenser only*
418 gallons per 24 hours
BTUs per hour* 8100
Refrigerant type R-12
Refrigerant charge 22 oz
Refrigerant pressures Air
cooled: discharge:125;
5 low, just before
harvest
Average amps 14.2
Cube per cycle Small =
198,
Medium = 56
Water solenoid valve flow
rate
.50 g.p.m.
Cycle time 17 to 25
minutes
*90/70
Water
cooled discharge pressure is 135 PSIG